Known Issues 24.3

<< Click to Display Table of Contents >>

Navigation:  Release Notes > Build 24.3 (Nov 2024) >

Known Issues 24.3

ArcEQuIS, Collect Enterprise, Collect Mobile, Desktop Applications, DQM, EDGE, EDP, Enterprise, EnviroInsite, Live, Professional, Reports, SPM

 

All known issues will be considered for fixing in a future release. Please see https://forum.earthsoft.com for current information.

 

ArcEQuIS

A Location Layer must be added to the map in addition to a Report Layer in order for labels to be displayed. The Location Layer may not perfectly align with the Report Layer's locations.

Most EQuIS software is digitally signed in EarthSoft's code signing certificate issued by a trusted certificate authority (DigiCert). However, the ArcEQuIS add-in is signed only with a self-signed certificate due to current limitations in Esri's ArcGIS software development kit (SDK) that prevent the use of a code-signing certificate stored in a cloud-based hardware security module (HSM).

Graphics By Location and Select Locations are unresponsive when used as a Linked Layer from a facility configured to the UTM_17N COORD_TYPE_CODE. The workaround for this behavior is to right-click the layer in the table of contents, opening the attribute table for the layer, which restores the expected functionality.

The attribute table for large reports is empty when the layer is added as a snapshot layer.

 

Collect Enterprise

The Allow Form Refresh check box does not return to the default value (i.e., unchecked) when switching templates while creating a new data form.

When building a formula using the Add Outer Function tool, the necessary nodes required for the outer function are not shown and a parameter count error is displayed.

The Drag/Drop functionality is not working when adjusting the Collect widget settings while using Mozilla Firefox.

When editing a form section that has previously been configured with Data Sets there is no clear indication of the previously selected Data Set configuration.

Clicking "Show Complete" on the Data Forms page results in the User Groups column becoming blank. A workaround is to click the "Refresh" button on the Data Forms page.

Form Summary Report pagination is incorrect when many records are present in the report.

Translation files cannot be used if downloaded using a computer set to a language other than English.

 

Collect Mobile

When a Time field is a column within a Table Form field, the AM/PM marker will switch unexpectedly when selecting a time in the 12:00 hour.

When a Selector field is a column within a Table Form field, all of the field's Options will be shown regardless of any Visible formula on those Options.

Using an Android device with regional settings that use a comma as the decimal separator, users cannot enter decimal values in decimal fields. The workaround for this issue is to install a third party keyboard and set it as the default keyboard.

Restoring a Collect backup made while "Remember my credentials" is enabled will automatically log in as the user who created the backup.

 

Desktop Applications

After clicking File or navigating to the backstage in some open EQuIS desktop applications (EQuIS Professional, SPM, and when connecting to an EQuIS database in EnviroInsite), single-clicking the Minimize/Maximize/Close buttons may only highlight the button. To minimize/maximize/close the applications, users may need to double-click the appropriate button.

 

DQM

A DQM Event will fail to save if it contains record(s) that have a CAS_RN with periods or commas.

DQM Exceptions Report is not translating to Languages other than English (LOTE).

 

EDGE

When Collect generates an EDGE EDD that contains files, the Organize EDGE Files and Photos feature will not organize the files as expected.

 

EDP

In the EQEDD format, when TestResults_v1.dilution_factor is blank, it uses the default value of "1.0". This works when culture settings are en-US, but results in an error when using culture settings that use a "," for their decimal separator (e.g., de-DE).

Link Mapper Status messages may be displayed in the incorrect order.

In the Facility Format, attempting to delete a row from within a section that does not contain a "task_code" column results in an error and the row is unable to be deleted.

When Windows display settings include both high scaling and high text size, text in the EDP ribbon may be cut off, although the buttons and drop-downs are still functional.

 

Enterprise

EDP EDD Upload Widget – Drag/drop functionality is not available.

Web Forms Widget – Inconsistent error message behavior upon Delete when different Related Records settings are configured between form sections of a template.

 

EnviroInsite

EnviroInsite is unable to reopen saved subsurface profile .vizx files.

 

Live

Weather Underground widget allows users to add multiple stations and does not provide notification that they are duplicate.

status.aspx – page shows an incorrect FAIL status for all Live File Processor Workflow EFD configurations.

Live Historical Chart Widget – When Remarks are added to data points, the datum values saved to the database are not correctly converted to UTC from the timezone configured for displaying data points, causing incorrect date range values.

 

Professional

Docs & Photos Form – XML-structured files downloaded through the Docs & Photos Form are missing the final ">" of the closing tag. To avoid issues, download these files via the EQuIS Blobber Form in EQuIS Professional or the Explorer widget in EQuIS Enterprise.

 

Reports

Analytical Results II - Statistics

oConfidence levels are reported at 95%, 97.5%, and 99.5% in the Confidence_90%, Confidence_95%, and Confidence_99% columns, respectively.

oFor a sample size of less than 10, the variance of S under normal approximation is based on the standard sample variance equation, rather than the EPA-specified method.

Reports with Additional Fields – Including RT_GROUP_MEMBER.CUSTOM_FIELD_1 through CUSTOM_FIELD_5 (added to the Schema in d31727) as Additional Fields will cause the report to fail with the "Invalid column name" message.

Statistics: Analytical Statistics (by Location) – The Mann-Kendall S value may be miscalculated due to alphanumeric date sorting of datasets.

 

SPM