Geotech (24.3)

<< Click to Display Table of Contents >>

Navigation:  Release Notes > Build 24.3 (Nov 2024) >

Geotech (24.3)

 

 


 

 

Geotech Reports – Logo Field Now Populates Correctly if CLIENT_LOCATION Is Empty in DT_TASK_PARAMETER [d40226]

Fixed an issue in Geotech reports that caused the logo at the bottom of the report to not appear when the client_location param_code in DT_TASK_PARAMETER was not present. 

 

 


 

 

Geotech Reports – New Consolidation Compression Curve Report [d41761]

Added new Geotech report that charts the Stress vs. Strain or Stress vs. Void Ratio results from a Consolidation test.

 

 


 

 

Geotech Reports – New Consolidation Sample and Load Results Report [d41303]

Created the new "Consolidation Sample and Load Results" geotechnical grid report that allows users to view information related to consolidation testing.

 

 


 

 

Geotech Reports – Shared Report Attributes – Added Name Manager fields from DT_FACILITY [d40349]

Updated EQuIS Geotech Reports to allow user to output fields from DT_FACILITY.

 

 


 

 

Geotech Reports – Shared Report Attributes – Displaying DT_GEO_TEST Fields [d41581]

Added data from DT_GEO_TEST to Shared Attributes in EQuIS Geotech Reports for the following fields: 
  • LAB_START_TEST_DATE
  • LAB_END_TEST_DATE
  • LAB_TEST_TECHNICIAN
  • LAB_TEST_LAB_CODE

 

 


 

 

Geotech_refvals Format – Added ST_GROUP_TYPE Section [d42412]

Added the ST_GROUP_TYPE section to the Geotech_refvals format.

 

 


 

 

Geotechnical Atterberg Limits Report – Added Option to Exclude Non-Plastic Samples from Graph [d41803]

Updated the Geotechnical Atterberg Limits Report to provide option for excluding non-plastic samples from the graph. This report must be republished. 

 

 


 

 

Geotechnical Atterberg Limits Report – Added Samples Parameter [d40370]

Added Samples as a report parameter to the Geotechnical Atterberg Limits Report to allow the selection of specific samples.

 

 


 

 

Geotechnical CPT Parameters Export Report – Resolved Duplicate Outputs [d42046]

Fixed a bug that caused duplicate values to be displayed in the Excel output for the Geotechnical CPT Parameters Export report.

 

 


 

 

Geotechnical DMT Parameters Export Report – Resolved Duplicate Outputs [d41701]

Fixed an issue that caused duplicate values to be displayed in the Excel output for the Geotechnical DMT Parameters Export report.

 

 


 

 

Geotechnical Gradation Hydrometer and Gradation Sieve Reports – Added Samples Parameter [d42538]

Added a Samples parameter to the "Geotechnical Gradation (Sieve) - ASTM D6913" and "Geotechnical Gradation (Hydrometer) - ASTM D7928" reports, which allows users to select individual samples to be included in the report output(s).

 

 


 

 

Geotechnical Grain Size Report – Added Samples Parameter [d40308]

Added Samples parameter to the Geotechnical Grain Size Report to allow users to select individual samples to display in their Grain Size Report output.

 

 


 

 

Geotechnical Sample Reports – Added "Reportable" Parameter to Filter Output Based on DT_GEO_RESULT.REPORTABLE_RESULT [d42340]

Added the "Reportable" parameter to the following Geotech reports:
  • Atterberg Limits
  • Atterberg Limits 3 Point
  • Compaction
  • Gradation (Hydrometer) - ASTM D7928
  • Gradation (Sieve) - ASTM D6913
  • Grain Size Analysis
  • Water Content vs. Depth

 

 


 

 

Geotechnical_v2 Format – Add DT_GEO_RESULT.REPORTABLE_RESULT Mappings for All Lab Sections [d42100]

Added Reportable_Result YN value to all lab sections in Geotechnical_v2 format. Child sections will inherit the value from its parent section (e.g., Atterberg_Readings will inherit the associated value in Atterberg).

 

 


 

 

Geotechnical_v2 Format – Added "strength_unit" to Unconf_Comp and Unconsolidated_Undrained Sections [d40192]

Added "strength_unit" field to Unconf_Compression and Unconsolidated_Undrained sections in the Geotechnical_v2 format.

 

 


 

 

Geotechnical_v2 Format – Added DT_GEO_TEST Fields to All Lab Sections [d41579]

Added the following DT_GEO_TEST fields to the lab sections of the Geotechnical_v2 format:
  • end_date
    • Database Mapping: DT_GEO_TEST.END_DATE
    • Comment: Date and time the test was completed
  • technician
    • Database Mapping: DT_GEO_TEST.TECHNICIAN
    • Comment: Name of the testing laboratory/organization
  • testing_lab
    • Lookup: RT_COMPANY
    • Database Mapping: DT_GEO_TEST.LAB_CODE
    • Comment: Testing laboratory/organization

 

 


 

 

Geotechnical_v2 Format – Added fields to Consolidation_Details and Consolidation_load_readings Sections [d40230]

Added new columns to two sections of the Geotechnical_v2 format:
  • final_saturation was added to Consolidation_Details section
  • time_unit was added to Consolidation_Load_Readings section

 

 


 

 

Geotechnical_v2 Format – Updated "calib_temp_units" to Be Lookup for RT_UNIT [d42300]

Updated the "calib_temp_units" field, in the Hydrometer section of the format, to be a lookup field that gets values from RT_UNIT.UNIT_CODE. Also increased the "calib_temp_units" field character limit to 15.

 

 


 

 

GeotechRefval EDD Format – Updated RefVal EDD with Additional Reference Value [d41174]

Added "final_saturation" and fixed the spelling of "initial_wet_density" for RT_GEO_RESULT_CODE in the Geotech_Refvals_EDD.xlsx file.