DQM (24.2)

<< Click to Display Table of Contents >>

Navigation:  Release Notes > Build 24.2 (Jul 2024) >

DQM (24.2)

 

 


 

 

DQM – Changing Apply Qualifier/Reason Code/Remark on Merged Qualifiers no Longer Overwrites All Qualifiers [d38186]

Fixed a bug that caused only one exception to be updated for results with multiple exceptions. This occurred when changing one of the following options on the All Results tab in DQM: 
  • Apply Qualifier
  • Apply Reason Code
  • Apply Remark

 

 


 

 

DQM – Modified Exceptions Failed to Save After Editing Apply Remark In a Saved Event [d38254]

Fixed a bug in DQM where a null Apply RC value caused a row in the DQM Event to not be able to be updated. DQM now saves blank reason codes as NULL when being added to DT_RESULT_DQM.REASON_CODE.

 

 


 

 

DQM – New DQM Basic QAPP File [d39554]

A new DQM Basic QAPP EDD file is available that is based on the USEPA 2020 National Functional Guidelines. The file is structured to work with the 7.24.1 and 7.24.2 Builds. See the DQM Basic QAPP article for more information.

 

 


 

 

DQM – Open In Process Event Produces "StartIndex cannot be larger than length of String" Error [d38265]

Fixed a bug in DQM where an error occurred if APPLY_REASON_CODEs are being merged and APPLY_REASON_CODE has been deleted in DT_RESULT_DQM.

 

 


 

 

DQM – Removed Case Sensitivity in DQM for Checks and Parameters [d38651]

Removed case sensitivity for Checks and Parameters in DQM.

 

 


 

 

DQM – Save Event – Error Added when Using MAGs with Duplicated MAG Members [d38357]

Added an error message when using the Method Analyte Groups (MAGs) Dataset Selection in DQM and the selected MAG(s) have duplicate MAG members.

 

 


 

 

DQM – SDG_Status Field Now Populates Correctly [d38345]

Fixed a bug where the DT_SDG.SDG_Status field was not populated when saving an event.

 

 


 

 

DQM Checks – Holding Time Check – No Missing Hold Time Limit Error when The Limit Is 999 [d38287]

Fixed a bug that caused a missing holding time control limit error when using 999 as a holding time control limit. Now holding time control limits with 999 will intentionally skip that Holding Time Type.

 

 


 

 

DQM Checks – Holding Time Check – Runs useRuleQualifier Parameter = N [d38225]

The DQM Holding Time Check will now execute when the useRuleQualifier parameter is set to 'N'.

 

 


 

 

DQM Checks – RPD Lab and RPD Field Checks – Incorrect Application of AD_MULTIPLIER_DL for Evaluated Value [d38396]

Fixed a bug for the RPD Lab Check and RPD Field Check where the evaluated result was not being displayed correctly when the absolute difference was calculated using the AD_MULTIPLIER_DL parameter.  

 

 


 

 

DQM Checks – Surrogate Recovery Check – "Index 0 is either negative or above rows count" Error When Saving DQM Event [d38226]

Fixed a bug in DQM that produced an "Index 0 is either negative or above rows count" error when running a Surrogate Recovery check on a dataset for the first time.

 

 


 

 

DQM Event Review Form – Added DETECT_FLAG [d38526]

Added the DETECT_FLAG column to the following tabs of the DQM Event Review Form:
  • Review Exceptions by Check
  • Review All Results
  • Review Samples and Results by Sample
  • Third Party Validation

 

 


 

 

DQM Event Review Form – Results by Sample Grids Selection Is Now Responsive After Save [d38458]

Fixed a bug when saving a DQM event in the Event Review Form that caused the Samples and the Results by Sample grids to become unresponsive.

 

 


 

 

DQM Report – DQM Exceptions Report by EDD – Modify EDD Ebatch Number Report Parameter [d38463]

Updated the "EDD Ebatch Number" parameter to "EDD Ebatch Number: (required)" in the DQM Exceptions Report by EDD.

 

 


 

 

DQM Report – DQM Exceptions Report by EDD – Triggered EIA Report Now Includes EBATCH [d38360]

Fixed a bug where the EBATCH field would not be populated when the DQM Exceptions Report by EDD was run as an EIA.

 

 


 

 

DQM Start Event Form – Manual Associations Persist [d38467]

Selected Manual Associations will no longer be lost if the Manual Associations button is clicked again.

 

 


 

 

DQM Start Event Form – Start Event Button Now Disables After Starting DQM Event [d38497]

To prevent errors, the Start Event button will now disable with updated text upon successfully starting a DQM event.