Add Action Levels to XY Charts

<< Click to Display Table of Contents >>

Navigation:  Professional > Tools & Charts > XY Charts >

Add Action Levels to XY Charts

Follow the steps below to add Action Levels to XY Charts.

 

1.In EQuIS Professional, click Reports in the Open group of the EQuIS Home Toolbar.

2.Select the Analytical Results II Report and click Open.

3.Click and select the following:

 

Parameters

Selection

Sample Date Range End

03/28/2017

Sample Matrix(es)

WG

Result Analyte Individual(s)

Tricholoroethylene

Result Units

ug/l

 

4.Type TCE WG ug/l in the blank User Reports field to save the query parameters; click Save.

5.Click Go to run the report. The results will be returned in grid format.

6.Click Reports in the Open group of the EQuIS Home Toolbar.

7.Select the Action Level Exceedance Report II by User Report and click Open.

8.Click and select the following:

 

Parameters

Selection

User Report

TCE WG ug/l, Analytical Results II

Action Level(s)

CLEANWATER INDUST

Exceedance Flag

xxx

 

9.Click Go to run the report.

10.Click XY Chart Graph-01(16) on the Action Level Exceedance menu.

11.In the Data pane, select the following:

 

Parameters

Selection

Dataset

Action Level Exceedance II by User Report

X-Axis

SAMPLE_DATE

Y-Axis

REPORT_RESULT_VALUE

Group Series By

CHEMICAL_NAME

Group Charts By

SYS_LOC_CODE

 

12.Click Add Series in the Data pane to display the trend plot.

 

Note: Setting the parameter Group Charts = SYS_LOC_CODE sorts the results by putting multiple tabs at the bottom of the Trend Plot. Select each tab to view the Analytical Results XY Chart for that chemical.

 

13.Select B-75.

14.In the Data pane, select the following:

 

Parameters

Selection

Dataset

Action Level Exceedance II by User

X-Axis

SAMPLE_DATE

Y-Axis

ACTION_LEVEL

Group Series By

ACTION_LEVEL_CODE

Group Charts By

SYS_LOC_CODE

 

15.Click Add Series in the Data pane to display the trend plot. The analytical results and action levels are present.

 

Note: The first chart is active whenever a new series is added to all the charts.